Product Specifications

Technical Specifications for Every Hexmodal Device

Detailed specifications for facilities engineers, procurement teams, and contractors evaluating Hexmodal for deployment.

Emergency Lights & Exit Signs

Specification
Detail
Model
HEX-W, HEX-N, HEX-A, HEX-A-C, HEX-A-R, HEX-C, HEX-X
Power Input
110–270 V AC
Mounting
Standard junction box; no special wiring
Testing
Automated monthly 30-sec and annual 90-min per NFPA 101 §7.9.3
Communication
Low-frequency encrypted radio to Hex-G gateway
Certification
UL listed, CMS-compliant
Battery Backup
Internal; monitored automatically
Report Format
AHJ and NFPA 101 aligned; digital; time-stamped
IT Requirements
None

Fire Extinguisher Monitor (HEX-F)

Specification
Detail
Compatible Extinguishers
Standard 5 lb, 10 lb, 20 lb ABC portable
Monitoring
Pressure, weight, tamper, obstruction, location
Report Includes
Gauge photo, pressure status, weight, obstruction status, timestamp
Mounting
Wall mount (ADA 5.5-inch protrusion) or inside existing cabinet
Installation Time
5–10 minutes; no wiring
Power
Battery powered
Alerts
Text, email, phone call; local sound alarm available
Communication
Low-frequency radio to Hex-G gateway
Compliance Standard
NFPA 10
IT Requirements
None

Cold Storage Monitors (HEX-T Series)

Specification
Detail
Model
HEX-T-C (refrigerator), HEX-T-R (room), HEX-T-ULT (ultra-low), HEX-T
Monitoring
Temperature (continuous); optional humidity
Probe
NIST-traceable; glass bead buffer bottle
Calibration
Free recertification included; probes replaced before expiration
Reading Interval
1-minute increments (configurable)
Battery Life
3+ years; free replacement included
Installation Time
5 minutes; no wiring
Communication
Low-frequency radio to Hex-G gateway
Compliance Standards
CMS, Joint Commission, FDA expectations
IT Requirements
None

Room Environment Monitor (HEX-P)

Specification
Detail
Monitoring
Pressure differential, temperature, humidity, door position
Door Sensor
HEX-D included
Reading Interval
1-minute increments (configurable)
Calibration
NIST-traceable; free replacement included
Battery Life
3+ years; free replacement included
Installation Time
10 minutes; no wiring
Communication
Low-frequency radio to Hex-G gateway
Compliance Standards
NFPA 99, ASHRAE 170, Joint Commission EC.02.05.01, DNV NIAHO
IT Requirements
None

Leak Detection (HEX-L)

Specification
Detail
Models
HEX-L-S (spot sensor), HEX-L-Z (zone sensor)
Detection Sensitivity
0.2 inches of water
Zone Coverage
Up to 30 ft with extension cables
Battery Life
5+ years; free replacement included
IP Rating
Dustproof and waterproof
Installation Time
5 minutes; no wiring
Communication
Low-frequency radio to Hex-G gateway
Alerts
Text, email, phone call
IT Requirements
None

Door Monitor (HEX-D)

Specification
Detail
Mounting
Double-sided tape or screws; any door
Battery Life
4–7 years
Tamper Detection
Yes; alerts administrator if dismounted
Communication
Direct connection to Hex-G gateway
IT Requirements
None

Hex-G Gateway

Reach us at support@hexmodal.com or 201-754-8048

Specification
Detail
Device Capacity
1,000+ devices
Coverage Area
250,000 sq ft indoor; up to 5 floors (2 up, 2 down)
Connectivity
Cellular (no WiFi, Ethernet, or IT network required)
Power
120 V AC standard outlet
Setup
Plug in and devices connect automatically
24/7 support, anytime you need it

Need Help With a Device?

Reach us at support@hexmodal.com or 201-754-8048

Questions About Compatibility or Installation?